HS Code: 901833
Anesthesia machine
Languages: 中文 English Español 日本語 한국어 Tiếng Việt ไทย Русский

📋 Code Structure

Chapter
Chapter 90 is the chapter in the HS classification system covering optical, photographic, cinematographic, measuring, checking, medical or surgical instruments and apparatus, and precision instruments and apparatus. This chapter covers an extremely broad scope, including optical elements, photographic equipment, measuring instruments, medical devices, industrial process control equipment, etc. Its core characteristic is that these goods are usually precision and technically complex, used for professional or scientific purposes. This chapter is clearly distinguished from Chapter 84 (mechanical appliances) and Chapter 85 (electrical equipment), emphasizing their instrument nature and their specialized use for medical and scientific research.
Heading
Heading 9018 covers medical, surgical, dental or veterinary instruments and appliances, including scintigraphic apparatus, other electro-medical apparatus and sight-testing instruments. This heading is the core classification position for medical devices, including diagnostic equipment, therapeutic equipment, surgical instruments, anesthesia equipment, etc. Its scope ranges from simple examination instruments to complex life support systems, but excludes apparatus for slaughtering animals (classified under Chapter 84) and general laboratory equipment (classified under other headings of Chapter 90).
Digit Breakdown
Code 901833 is a six-digit subheading. The first 2 digits '90' represent Chapter 90 (optical, medical and other instruments); digits 3-4 '18' represent heading 9018 (medical, surgical, dental or veterinary instruments and appliances); digits 5-6 '33' represent subheading 9018.33, namely anesthesia machines. Specifically, 9018 is subdivided into multiple subheadings, such as 9018.11 electrocardiographs, 9018.12 ultrasonic diagnostic apparatus, etc., while 9018.33 specifically refers to anesthesia machines, used to administer general or local anesthesia to patients and maintain respiration during surgical procedures. This subheading has a clear direction in the HS classification, distinguishing it from other anesthesia-related equipment such as anesthesia ventilators (which may be classified under 9019) or anesthetic drugs (classified under Chapter 30).
Classification Basis
Anesthesia machines are classified under 9018.33 because they are essentially medical-specific equipment used in operating rooms to administer anesthesia and manage respiration, meeting the definition of heading 9018 'medical, surgical instruments and appliances.' They are different from the mechano-therapy appliances or respirators of 9019, and also different from general-purpose pumps or compressors of Chapter 84. An anesthesia machine is a complex medical device integrating gas delivery, vaporizers, breathing circuits and monitoring systems, whose core function is anesthesia, therefore 9018.33 is the most precise classification.

📝 Declaration Elements

Product name (Chinese and English)
The standard name of the declared commodity, '麻醉机' in Chinese and 'Anesthesia machine' in English, which must be consistent with the physical nameplate.
⚠️ Mistakenly written as '麻醉呼吸机' or '呼吸麻醉机', leading to classification disputes.
Use
Explain the clinical application scenario of the device, such as 'used for general anesthesia in operating rooms' or 'used for ICU respiratory support'.
⚠️ Vaguely filling in 'medical use' without specifying the anesthesia or respiratory support function.
Working principle
Briefly describe how the device works, such as 'converts liquid anesthetic into gas through a vaporizer, mixes it with oxygen, and delivers it to the patient through a breathing circuit'.
⚠️ Only writing 'electronically controlled' without explaining the anesthetic gas delivery mechanism.
Brand (Chinese and English)
Fill in the brand name of the equipment manufacturer, such as 'Drager', 'GE', etc., which must be consistent with the registration certificate.
⚠️ Confusing brand with model, or filling in the agent's brand instead of the manufacturer's brand.
Model
Fill in the specific model, such as 'Fabius GS', which should be consistent with the model on the medical device registration certificate.
⚠️ Incomplete model entry or inconsistency with the registration certificate.
Whether it includes an anesthetic gas monitoring module
Explain whether the device integrates anesthetic gas concentration monitoring functionality, which affects classification and regulatory conditions.
⚠️ Failure to declare truthfully, leading customs to question the device's function.
Medical device registration certificate number
Fill in the medical device registration certificate number issued by the National Medical Products Administration to prove the device is legally marketed.
⚠️ Filling in an expired or incorrect registration certificate number.
Quantity and unit
Fill in the import quantity and unit of measurement, usually 'units'.
⚠️ Misusing 'sets' or 'pieces' as the unit, inconsistent with the invoice.
Example:
Product name: Anesthesia machine; Use: For general anesthesia and respiratory management in operating rooms; Working principle: Converts anesthetics such as sevoflurane into gas through a vaporizer, mixes it with oxygen, delivers it to the patient through a breathing circuit, and monitors vital signs; Brand: Drager; Model: Fabius GS; Whether it includes an anesthetic gas monitoring module: Yes; Medical device registration certificate number: National Medical Device Import Registration 20173543012; Quantity: 2 units.
Common Mistakes:

🎯 Classification Logic

Basis
The core basis for classification is whether the main function of the device is anesthesia. According to HS notes, 9018.33 specifically refers to anesthesia machines, i.e., equipment used to deliver anesthetic gases and/or volatile anesthetics to patients, usually including vaporizers, breathing circuits, flowmeters and monitoring systems. If the device is only used for respiratory support without anesthesia function, it should be classified under 9019.20 (respirators). If the device has both anesthesia and respiratory functions, it is still classified according to its main function. In addition, reference should be made to the 'Medical Device Classification Catalog' to confirm its management category.
Confused Codes:
901920 - Respirators
Respirators are mainly used to assist or replace the patient's spontaneous breathing and do not have anesthetic gas delivery function; anesthesia machines have anesthetic gas vaporization and delivery systems, with anesthesia as the core.
901819 - Other electro-medical apparatus
901819 is a residual subheading covering electro-medical equipment not otherwise specified; anesthesia machines already have a specific subheading 901833, so they are not classified under 901819.
901890 - Other medical instruments
901890 covers non-electrical or unspecified medical instruments, such as surgical instruments; anesthesia machines are electro-medical equipment and are already specifically listed, so they are not classified here.
847989 - Other mechanical appliances
If an anesthesia machine is only used as a gas mixing machine without medical use, it might be classified under Chapter 84; but as medical equipment, it must be classified under Chapter 90.
Self-Check:

❓ FAQ

Q: What is the difference in HS codes between anesthesia machines and ventilators?
A: Anesthesia machines are classified under 901833, and ventilators under 901920. The main difference lies in function: anesthesia machines are used to deliver anesthetic gases and maintain anesthesia, while ventilators are used to assist or control breathing. If a device has both functions, it should be judged according to its main function, usually based on whether it has an anesthetic gas vaporization system.
Q: What regulatory documents are required to import anesthesia machines?
A: Importing anesthesia machines usually requires a medical device registration certificate (or filing certificate), import medical device customs clearance form, certificate of origin, invoice, packing list, etc. Specific regulatory conditions can be checked in the 'Import and Export Tariff' and 'Regulatory Document Code Table' published by the General Administration of Customs, or by using the customs classification pre-ruling service.
Q: How to check the import tax rate for anesthesia machines?
A: Import tax rates include the most-favored-nation rate, interim rate, value-added tax and consumption tax. You can log on to the official website of the General Administration of Customs or China International Trade Single Window and enter HS code 901833 to check real-time tax rates. Note that tax rates may be adjusted with policy changes, and the rate at the time of declaration should prevail.
Q: If an anesthesia machine is classified under 901833, is a classification pre-ruling required?
A: If there are doubts about classification or the device functions are complex, it is recommended to apply for a classification pre-ruling. A pre-ruling can determine the code in advance and avoid declaration errors. Applications can be submitted through the General Administration of Customs or directly affiliated customs, providing equipment technical data, manuals, etc.
Q: Can used anesthesia machines be imported?
A: China allows the import of used medical devices, but they must comply with the 'Regulations on the Supervision and Administration of Medical Devices' and the 'Measures for the Inspection and Supervision of Imported Used Mechanical and Electrical Products'. Used anesthesia machines must obtain a medical device registration certificate and pass inspection and quarantine. Some used equipment may be prohibited from import, so it is advisable to consult customs and drug regulatory authorities in advance.
Q: How are anesthesia machine accessories (such as vaporizers, breathing circuits) classified?
A: The classification of accessories depends on whether they are dedicated. Vaporizers, as dedicated parts of anesthesia machines, if imported separately, may be classified under 901890 (other medical instruments) or as parts; breathing circuits, if made of plastic, may be classified under 3917 or 9018. It is recommended to judge based on specific materials and uses, and apply for a pre-ruling if necessary.
Q: What should be noted when selling anesthesia machines through cross-border e-commerce?
A: Anesthesia machines are medical devices, and cross-border e-commerce retail imports must comply with the 'List of Cross-border E-commerce Retail Imported Goods'. Currently, anesthesia machines are not included in the list, so they generally cannot be imported through cross-border e-commerce retail. Enterprises can import through general trade and obtain the corresponding qualifications.
Q: What certifications are required to export anesthesia machines to the EU?
A: Exporting to the EU requires CE certification, complying with the Medical Device Regulation (MDR) or the previous MDD. Anesthesia machines are usually Class IIb or Class III, requiring notified body involvement. Technical files, clinical evaluation, ISO 13485 quality system certificates, etc. are also required. For specifics, consult professional certification bodies.
⚠️ Disclaimer: HS code classification, declaration elements, tariff rates and regulatory conditions on this page are for reference only and do not constitute legal advice on customs classification. Tariff rates and regulations are subject to change; the latest announcements from the General Administration of Customs and on-site determinations shall prevail. Please consult professional customs brokers or customs authorities before import/export.