Chapter 70 covers glass and glassware, from raw glass (such as glass blocks, tubes, rods) to various finished products (such as glassware, glass fiber, technical glass products). This chapter divides tariff headings by processing depth and use, including the manufacture, processing of glass and special-purpose glass products, but excludes glass optical elements (Chapter 90), glass toys (Chapter 95), etc. Heading 7010 includes glass ampoules, tubes, bottles, jars, pots, carboys, vials, stoppers, lids and other glass containers, used for the transport or packing of goods. This heading covers various glass containers, whether or not processed, but mainly used for commercial packing or transport, and excludes household glassware (such as drinking glasses, tableware) or laboratory glassware. The first 2 digits 70 represent Chapter 70 (Glass and glassware). Digits 3-4, 10, represent heading 7010 (Glass ampoules, tubes, bottles, jars, pots, carboys, vials, stoppers, lids and other glass containers). Digits 5-6, 10, represent subheading 7010.10, specifically glass ampoules. An ampoule is a small glass container, usually used to hold injectable medicinal liquids or vaccines, sealed and broken open for use. Glass ampoules are classified under 7010.10 because they are small glass containers mainly used for pharmaceutical packaging. Differences from adjacent codes: 7010.20 is glass stoppers and lids; 7010.90 is other glass containers (such as bottles, jars). Ampoules have a specific use (pharmaceutical) and are usually small-capacity, sealed, and easy to break, so they are listed under a separate subheading.
Chapter
Chapter 70 covers glass and glassware, from raw glass (such as glass blocks, tubes, rods) to various finished products (such as glassware, glass fiber, technical glass products). This chapter divides tariff headings by processing depth and use, including the manufacture, processing of glass and special-purpose glass products, but excludes glass optical elements (Chapter 90), glass toys (Chapter 95), etc.
Heading
Heading 7010 includes glass ampoules, tubes, bottles, jars, pots, carboys, vials, stoppers, lids and other glass containers, used for the transport or packing of goods. This heading covers various glass containers, whether or not processed, but mainly used for commercial packing or transport, and excludes household glassware (such as drinking glasses, tableware) or laboratory glassware.
Digit Breakdown
The first 2 digits 70 represent Chapter 70 (Glass and glassware). Digits 3-4, 10, represent heading 7010 (Glass ampoules, tubes, bottles, jars, pots, carboys, vials, stoppers, lids and other glass containers). Digits 5-6, 10, represent subheading 7010.10, specifically glass ampoules. An ampoule is a small glass container, usually used to hold injectable medicinal liquids or vaccines, sealed and broken open for use.
Classification Basis
Glass ampoules are classified under 7010.10 because they are small glass containers mainly used for pharmaceutical packaging. Differences from adjacent codes: 7010.20 is glass stoppers and lids; 7010.90 is other glass containers (such as bottles, jars). Ampoules have a specific use (pharmaceutical) and are usually small-capacity, sealed, and easy to break, so they are listed under a separate subheading.
📝 Declaration Elements
Product Name: The specific name of the declared commodity, such as "glass ampoule", should accurately reflect the product's attributes. Material: Declare the type of glass, such as "neutral borosilicate glass", "soda-lime glass", etc., which affects classification. Use: Explain the final use of the ampoule, such as "for holding injections", "for vaccine packaging", etc. Capacity: Declare the capacity of the ampoule, such as "1ml", "2ml", "5ml", etc., which affects subheading determination. Sterile or Not: Declare whether it has undergone sterile treatment, such as "sterile" or "non-sterile", which affects regulatory conditions. Brand: Declare the brand name, such as "Schott", "Corning", etc.; if no brand, fill in "none". Model: Declare the product model or specification, such as "Type A", "Type B", etc. Product Name: Glass ampoule; Material: Neutral borosilicate glass; Use: For holding injectable medicinal liquids; Capacity: 2ml; Sterile or Not: Non-sterile; Brand: None; Model: Type A. Misdeclaring ampoules as glass bottles, leading to incorrect classification under 7010.90. Failure to state capacity, which may result in customs requiring supplementary declaration. Ignoring sterile status, affecting regulatory conditions (such as pharmaceutical clearance form). Material declaration not specific, such as only writing "glass", which may trigger classification doubts.
Product Name
The specific name of the declared commodity, such as "glass ampoule", should accurately reflect the product's attributes.
⚠️ Misdeclared as "glass bottle" or "glass tube", without clarifying the ampoule's use.
Material
Declare the type of glass, such as "neutral borosilicate glass", "soda-lime glass", etc., which affects classification.
⚠️ Only writing "glass", without specifying the specific composition, leading to classification disputes.
Use
Explain the final use of the ampoule, such as "for holding injections", "for vaccine packaging", etc.
⚠️ Vague description of use, such as "for packaging", without clarifying the pharmaceutical use.
Capacity
Declare the capacity of the ampoule, such as "1ml", "2ml", "5ml", etc., which affects subheading determination.
⚠️ Failure to provide capacity, or incorrect unit, such as "1 gram".
Sterile or Not
Declare whether it has undergone sterile treatment, such as "sterile" or "non-sterile", which affects regulatory conditions.
⚠️ Ignoring the sterile status, leading to failure to declare relevant regulatory documents.
Brand
Declare the brand name, such as "Schott", "Corning", etc.; if no brand, fill in "none".
⚠️ Confusing brand with manufacturer, or filling in incorrectly.
Model
Declare the product model or specification, such as "Type A", "Type B", etc.
⚠️ Incomplete model filling or inconsistency with the actual product.
Example: Product Name: Glass ampoule; Material: Neutral borosilicate glass; Use: For holding injectable medicinal liquids; Capacity: 2ml; Sterile or Not: Non-sterile; Brand: None; Model: Type A.
Common Mistakes:
Misdeclaring ampoules as glass bottles, leading to incorrect classification under 7010.90.
Failure to state capacity, which may result in customs requiring supplementary declaration.
Material declaration not specific, such as only writing "glass", which may trigger classification doubts.
🎯 Classification Logic
Core basis for classification: The product is a glass ampoule, a small glass container mainly used for pharmaceutical packaging. According to the General Rules for HS classification, it is classified under Chapter 70 by material and use. Heading 7010 covers glass containers, and subheading 7010.10 specifically refers to ampoules. It is necessary to confirm whether the product is an ampoule (rather than an ordinary glass bottle) and whether it is used for transport or packing. 7010.20 Glass stoppers and lids: 7010.20 is glass stoppers and lids, used to close containers; while 7010.10 is the ampoule itself, the main body of the container, and the two have different functions. 7010.90 Other glass containers: 7010.90 includes glass bottles, jars, etc., but ampoules have a specific shape (small capacity, easy to break) and pharmaceutical use, so they are listed separately. 7017.10 Laboratory glassware: 7017.10 is laboratory glassware, such as beakers, test tubes; although ampoules can be used in laboratories, their main use is pharmaceutical packaging, so they are classified under 7010.10. 3004.90 Medicaments: 3004.90 is ampoules already filled with medicaments; if the ampoule already contains medicaments, it is classified under Chapter 30, not 7010.10. Is it a glass ampoule? Is it used for holding medicaments? Is the capacity clear? Has it undergone sterile treatment? Has it already been filled with medicaments?
Basis
Core basis for classification: The product is a glass ampoule, a small glass container mainly used for pharmaceutical packaging. According to the General Rules for HS classification, it is classified under Chapter 70 by material and use. Heading 7010 covers glass containers, and subheading 7010.10 specifically refers to ampoules. It is necessary to confirm whether the product is an ampoule (rather than an ordinary glass bottle) and whether it is used for transport or packing.
Confused Codes:
7010.20 - Glass stoppers and lids
7010.20 is glass stoppers and lids, used to close containers; while 7010.10 is the ampoule itself, the main body of the container, and the two have different functions.
7010.90 - Other glass containers
7010.90 includes glass bottles, jars, etc., but ampoules have a specific shape (small capacity, easy to break) and pharmaceutical use, so they are listed separately.
7017.10 - Laboratory glassware
7017.10 is laboratory glassware, such as beakers, test tubes; although ampoules can be used in laboratories, their main use is pharmaceutical packaging, so they are classified under 7010.10.
3004.90 - Medicaments
3004.90 is ampoules already filled with medicaments; if the ampoule already contains medicaments, it is classified under Chapter 30, not 7010.10.
Self-Check:
✓ Is it a glass ampoule?
✓ Is it used for holding medicaments?
✓ Is the capacity clear?
✓ Has it undergone sterile treatment?
✓ Has it already been filled with medicaments?
❓ FAQ
What is the HS code for glass ampoules? The HS code for glass ampoules is 7010.10, belonging to Chapter 70 glass and glassware; heading 7010 covers glass containers, and subheading 7010.10 specifically refers to ampoules. How to distinguish ampoules from glass bottles? Ampoules are usually small-capacity, sealed, easy-to-break glass containers, mainly used for pharmaceutical packaging; glass bottles have larger capacity and a wide range of uses. For classification, ampoules are classified under 7010.10, and glass bottles under 7010.90. Which code should ampoules already filled with medicaments be classified under? Ampoules already filled with medicaments should be classified under Chapter 30 medicaments, with the specific subheading determined by the type of medicament, such as 3004.90. Empty unfilled ampoules are classified under 7010.10. What elements are required to declare glass ampoules? Product name, material, use, capacity, sterile or not, brand, model, etc. are required. The material should be specific, such as neutral borosilicate glass; the use should be clearly stated as pharmaceutical packaging. How to check the import tariff rate for glass ampoules? Tariff rates change and can be checked through the official website of the General Administration of Customs, China International Trade Single Window, or by consulting a customs broker for the latest rates. Note tariffs, value-added tax, and possible consumption tax. Are there regulatory conditions for glass ampoules? Pharmaceutical regulatory conditions may be involved, such as sterile ampoules requiring a pharmaceutical clearance form. The specific regulatory conditions depend on the use and status of the ampoule; it is recommended to check the latest Import and Export Tariff or consult customs. Does the material of the ampoule affect classification? The material itself does not change the HS code, but different glass materials may affect the tariff rate or regulatory conditions. The material should be truthfully provided during declaration, such as neutral borosilicate glass, soda-lime glass, etc. How to declare glass ampoules sold via cross-border e-commerce? Ampoules sold via cross-border e-commerce need to be declared under general trade or cross-border e-commerce models, with complete declaration elements provided, and comply with pharmaceutical regulatory provisions. It is recommended to understand the destination country's requirements in advance.
Q: What is the HS code for glass ampoules?
A: The HS code for glass ampoules is 7010.10, belonging to Chapter 70 glass and glassware; heading 7010 covers glass containers, and subheading 7010.10 specifically refers to ampoules.
Q: How to distinguish ampoules from glass bottles?
A: Ampoules are usually small-capacity, sealed, easy-to-break glass containers, mainly used for pharmaceutical packaging; glass bottles have larger capacity and a wide range of uses. For classification, ampoules are classified under 7010.10, and glass bottles under 7010.90.
Q: Which code should ampoules already filled with medicaments be classified under?
A: Ampoules already filled with medicaments should be classified under Chapter 30 medicaments, with the specific subheading determined by the type of medicament, such as 3004.90. Empty unfilled ampoules are classified under 7010.10.
Q: What elements are required to declare glass ampoules?
A: Product name, material, use, capacity, sterile or not, brand, model, etc. are required. The material should be specific, such as neutral borosilicate glass; the use should be clearly stated as pharmaceutical packaging.
Q: How to check the import tariff rate for glass ampoules?
A: Tariff rates change and can be checked through the official website of the General Administration of Customs, China International Trade Single Window, or by consulting a customs broker for the latest rates. Note tariffs, value-added tax, and possible consumption tax.
Q: Are there regulatory conditions for glass ampoules?
A: Pharmaceutical regulatory conditions may be involved, such as sterile ampoules requiring a pharmaceutical clearance form. The specific regulatory conditions depend on the use and status of the ampoule; it is recommended to check the latest Import and Export Tariff or consult customs.
Q: Does the material of the ampoule affect classification?
A: The material itself does not change the HS code, but different glass materials may affect the tariff rate or regulatory conditions. The material should be truthfully provided during declaration, such as neutral borosilicate glass, soda-lime glass, etc.
Q: How to declare glass ampoules sold via cross-border e-commerce?
A: Ampoules sold via cross-border e-commerce need to be declared under general trade or cross-border e-commerce models, with complete declaration elements provided, and comply with pharmaceutical regulatory provisions. It is recommended to understand the destination country's requirements in advance.
⚠️ Disclaimer: HS code classification, declaration elements, tariff rates and regulatory conditions on this page are for reference only and do not constitute legal advice on customs classification. Tariff rates and regulations are subject to change; the latest announcements from the General Administration of Customs and on-site determinations shall prevail. Please consult professional customs brokers or customs authorities before import/export.