Chapter 85 covers electrical machinery and equipment and parts thereof; sound recorders and reproducers, television image and sound recorders and reproducers, and parts and accessories of such articles. This chapter is the most concentrated chapter in the HS classification for electromechanical products, involving various types of equipment for the production, conversion, storage, transmission, and utilization of electrical energy. Cables, as carriers of electrical energy transmission, are classified in this chapter if the insulating material is plastic or rubber; if they are optical fiber cables, they are classified in Chapter 90. Heading 8544 covers insulated (including enamelled or anodised) wire, cable (including coaxial cable) and other insulated electric conductors, whether or not fitted with connectors; optical fibre cables made up of individually sheathed fibres, whether or not assembled with electric conductors or fitted with connectors. However, this heading does not include optical fibre cables (classified in 9001) and wiring harnesses with connectors (if classified according to specific use). 854449 is among them for other electric conductors, for a voltage not exceeding 1000 V. Code 854449 is a 6-digit subheading. The first 2 digits 85 indicate Chapter 85 (electrical machinery and equipment and parts thereof). Digits 3-4, 44, indicate heading 8544 (insulated wire, cable and other insulated electric conductors). The 5th digit 4 indicates subheading 85444 (other insulated wire, cable, for a voltage not exceeding 1000 V), which is further subdivided: 854441 (fitted with connectors), 854442 (not fitted with connectors but for specific uses? Actually needs verification, but according to common structure, the 5th digit 4 represents other cable for a voltage ≤1000 V, and the 6th digit 9 represents other). Note: Subheading 854449 specifically refers to "other" cable, usually meaning voltage ≤1000 V, not fitted with connectors, not ignition wiring sets, etc. It needs to be confirmed in conjunction with the latest version of the customs tariff. The goods are cables for a voltage not exceeding 1000 V, not fitted with connectors, and do not belong to ignition wiring sets or other specific subheadings (such as 854411 winding wire, 854420 coaxial cable, 854430 ignition wiring sets, etc.). Therefore, they are classified under 854449. If the voltage exceeds 1000 V, they are classified under 854460; if they are coaxial cables, under 854420; if they are cables fitted with connectors, they may be classified under 854442 or 854449? Actually, are those fitted with connectors also classified under 854442? Note: Subheading 854442 is "other electric wire, cable, for a voltage ≤1000 V, fitted with connectors", while 854449 is "other, not fitted with connectors". Therefore, this code specifically refers to other cables not fitted with connectors, for a voltage ≤1000 V.
Chapter
Chapter 85 covers electrical machinery and equipment and parts thereof; sound recorders and reproducers, television image and sound recorders and reproducers, and parts and accessories of such articles. This chapter is the most concentrated chapter in the HS classification for electromechanical products, involving various types of equipment for the production, conversion, storage, transmission, and utilization of electrical energy. Cables, as carriers of electrical energy transmission, are classified in this chapter if the insulating material is plastic or rubber; if they are optical fiber cables, they are classified in Chapter 90.
Heading
Heading 8544 covers insulated (including enamelled or anodised) wire, cable (including coaxial cable) and other insulated electric conductors, whether or not fitted with connectors; optical fibre cables made up of individually sheathed fibres, whether or not assembled with electric conductors or fitted with connectors. However, this heading does not include optical fibre cables (classified in 9001) and wiring harnesses with connectors (if classified according to specific use). 854449 is among them for other electric conductors, for a voltage not exceeding 1000 V.
Digit Breakdown
Code 854449 is a 6-digit subheading. The first 2 digits 85 indicate Chapter 85 (electrical machinery and equipment and parts thereof). Digits 3-4, 44, indicate heading 8544 (insulated wire, cable and other insulated electric conductors). The 5th digit 4 indicates subheading 85444 (other insulated wire, cable, for a voltage not exceeding 1000 V), which is further subdivided: 854441 (fitted with connectors), 854442 (not fitted with connectors but for specific uses? Actually needs verification, but according to common structure, the 5th digit 4 represents other cable for a voltage ≤1000 V, and the 6th digit 9 represents other). Note: Subheading 854449 specifically refers to "other" cable, usually meaning voltage ≤1000 V, not fitted with connectors, not ignition wiring sets, etc. It needs to be confirmed in conjunction with the latest version of the customs tariff.
Classification Basis
The goods are cables for a voltage not exceeding 1000 V, not fitted with connectors, and do not belong to ignition wiring sets or other specific subheadings (such as 854411 winding wire, 854420 coaxial cable, 854430 ignition wiring sets, etc.). Therefore, they are classified under 854449. If the voltage exceeds 1000 V, they are classified under 854460; if they are coaxial cables, under 854420; if they are cables fitted with connectors, they may be classified under 854442 or 854449? Actually, are those fitted with connectors also classified under 854442? Note: Subheading 854442 is "other electric wire, cable, for a voltage ≤1000 V, fitted with connectors", while 854449 is "other, not fitted with connectors". Therefore, this code specifically refers to other cables not fitted with connectors, for a voltage ≤1000 V.
📝 Declaration Elements
Product Name: The specific name of the declared goods, such as "power cable", "control cable", "communication cable", etc., which must be consistent with the actual goods. Use: Explain the final use scenario of the cable, such as "for power transmission", "for internal connection of equipment", "for communication signal transmission", etc. Voltage: Clearly state the rated voltage of the cable, which must be a specific value not exceeding 1000 V, such as "220V", "380V", "600V", etc. Whether Fitted with Connectors: Declare whether the cable is fitted with connectors, plugs, etc. Classification differs between fitted with connectors and not fitted with connectors. Conductor Material: State the material of the conductor, such as "copper", "aluminum", etc., which affects classification and customs valuation. Insulation Material: State the material of the insulation layer, such as "PVC", "rubber", "cross-linked polyethylene", etc. Model Specification: Declare the model, number of cores, cross-sectional area, and other specifications of the cable, such as "YJV 3×25mm²". Brand: Declare the brand or manufacturer name of the cable; if there is no brand, fill in "no brand". Product Name: Power cable; Use: For power transmission at rated voltage 0.6/1kV; Voltage: 600V; Whether fitted with connectors: Not fitted with connectors; Conductor material: Copper; Insulation material: Cross-linked polyethylene; Model specification: YJV 3×25mm²; Brand: XX. Inaccurate voltage declaration: Misreporting a cable exceeding 1000 V as not exceeding 1000 V, leading to classification errors. Ignoring connector status: Cables fitted with connectors should be classified under 854442, and only those not fitted with connectors under 854449. Vague material description: Conductor or insulation material filled in too generally, which may trigger customs queries. Non-specific use declaration: Failure to state the specific use scenario, affecting classification judgment. Missing model specification: Unable to verify the technical parameters of the cable, which may cause customs clearance delays.
Product Name
The specific name of the declared goods, such as "power cable", "control cable", "communication cable", etc., which must be consistent with the actual goods.
⚠️ Incorrectly declaring as "wire" or "wire rod", leading to classification disputes.
Use
Explain the final use scenario of the cable, such as "for power transmission", "for internal connection of equipment", "for communication signal transmission", etc.
⚠️ Vaguely filling in "industrial use" without specific explanation, affecting classification.
Voltage
Clearly state the rated voltage of the cable, which must be a specific value not exceeding 1000 V, such as "220V", "380V", "600V", etc.
⚠️ Filling in "low voltage" or "high voltage" without providing a specific voltage value.
Whether Fitted with Connectors
Declare whether the cable is fitted with connectors, plugs, etc. Classification differs between fitted with connectors and not fitted with connectors.
⚠️ Misreporting a cable not fitted with connectors as fitted with connectors, or vice versa.
Conductor Material
State the material of the conductor, such as "copper", "aluminum", etc., which affects classification and customs valuation.
⚠️ Writing only "metal" without specifying the specific material.
Insulation Material
State the material of the insulation layer, such as "PVC", "rubber", "cross-linked polyethylene", etc.
⚠️ Filling in "plastic", which is too broad.
Model Specification
Declare the model, number of cores, cross-sectional area, and other specifications of the cable, such as "YJV 3×25mm²".
⚠️ Incomplete model filling, making it impossible to determine specific parameters.
Brand
Declare the brand or manufacturer name of the cable; if there is no brand, fill in "no brand".
⚠️ Brand inconsistent with the actual one, or omitted.
Example: Product Name: Power cable; Use: For power transmission at rated voltage 0.6/1kV; Voltage: 600V; Whether fitted with connectors: Not fitted with connectors; Conductor material: Copper; Insulation material: Cross-linked polyethylene; Model specification: YJV 3×25mm²; Brand: XX.
Common Mistakes:
Inaccurate voltage declaration: Misreporting a cable exceeding 1000 V as not exceeding 1000 V, leading to classification errors.
Ignoring connector status: Cables fitted with connectors should be classified under 854442, and only those not fitted with connectors under 854449.
Vague material description: Conductor or insulation material filled in too generally, which may trigger customs queries.
Non-specific use declaration: Failure to state the specific use scenario, affecting classification judgment.
Missing model specification: Unable to verify the technical parameters of the cable, which may cause customs clearance delays.
🎯 Classification Logic
The core criteria for classification are: 1) whether the voltage does not exceed 1000 V; 2) whether it is fitted with connectors; 3) whether it belongs to specific types such as coaxial cable, ignition wiring sets, winding wire, etc. Only insulated cables that simultaneously meet voltage ≤1000 V, not fitted with connectors, and not of specific types are classified under 854449. If the voltage exceeds 1000 V, classify under 854460; if it is a coaxial cable, under 854420; if it is an ignition wiring set, under 854430; if it is a cable fitted with connectors, under 854442. 854442 Other electric wire, cable, for a voltage ≤1000 V, fitted with connectors: The core difference from 854449 is whether it is fitted with connectors. Cables fitted with connectors (such as with plugs, connectors) are classified under 854442, and those not fitted with connectors under 854449. 854460 Other electric wire, cable, for a voltage >1000 V: Cables with voltage exceeding 1000 V are classified under 854460, while 854449 only applies to cables with voltage ≤1000 V. 854420 Coaxial cable and other coaxial electric conductors: Coaxial cables, regardless of voltage, are classified under 854420, not under 854449. 854430 Ignition wiring sets and other wiring sets: Ignition wiring sets used in vehicles, aircraft, etc. are classified under 854430, while 854449 is for general insulated cables. 854411 Winding wire: Winding wire (such as enamelled wire) is classified under 854411, while 854449 is for other cables. Is the voltage clearly not exceeding 1000 V? Is the cable not fitted with connectors? Does it not belong to coaxial cable, ignition wiring sets, or winding wire? Have the conductor and insulation materials been accurately declared? Is the model specification complete?
Basis
The core criteria for classification are: 1) whether the voltage does not exceed 1000 V; 2) whether it is fitted with connectors; 3) whether it belongs to specific types such as coaxial cable, ignition wiring sets, winding wire, etc. Only insulated cables that simultaneously meet voltage ≤1000 V, not fitted with connectors, and not of specific types are classified under 854449. If the voltage exceeds 1000 V, classify under 854460; if it is a coaxial cable, under 854420; if it is an ignition wiring set, under 854430; if it is a cable fitted with connectors, under 854442.
Confused Codes:
854442 - Other electric wire, cable, for a voltage ≤1000 V, fitted with connectors
The core difference from 854449 is whether it is fitted with connectors. Cables fitted with connectors (such as with plugs, connectors) are classified under 854442, and those not fitted with connectors under 854449.
854460 - Other electric wire, cable, for a voltage >1000 V
Cables with voltage exceeding 1000 V are classified under 854460, while 854449 only applies to cables with voltage ≤1000 V.
854420 - Coaxial cable and other coaxial electric conductors
Coaxial cables, regardless of voltage, are classified under 854420, not under 854449.
854430 - Ignition wiring sets and other wiring sets
Ignition wiring sets used in vehicles, aircraft, etc. are classified under 854430, while 854449 is for general insulated cables.
854411 - Winding wire
Winding wire (such as enamelled wire) is classified under 854411, while 854449 is for other cables.
Self-Check:
✓ Is the voltage clearly not exceeding 1000 V?
✓ Is the cable not fitted with connectors?
✓ Does it not belong to coaxial cable, ignition wiring sets, or winding wire?
✓ Have the conductor and insulation materials been accurately declared?
✓ Is the model specification complete?
❓ FAQ
How to query the regulatory conditions and tax rates corresponding to HS code 854449? You can query the regulatory conditions (such as whether CCC certification, export license, etc. are required) and tax rates for this code through the official website of the General Administration of Customs of China or the "Single Window". Tax rates will be adjusted according to policies, and it is recommended to refer to the latest "Import and Export Tariff of the People's Republic of China". What is the difference in classification between cables fitted with connectors and those not fitted with connectors? Cables fitted with connectors (such as with plugs, connectors) are classified under 854442, and those not fitted with connectors under 854449. During classification, it is necessary to carefully check whether the physical item is fitted with connectors to avoid incorrect declaration. Under which code should a cable with a voltage of exactly 1000 V be classified? Cables with voltage not exceeding 1000 V (including 1000 V) are classified under 854449 (not fitted with connectors) or 854442 (fitted with connectors). If the voltage exceeds 1000 V, they are classified under 854460. Are communication cables classified under 854449? If communication cables are coaxial cables, they are classified under 854420; if they are other insulated cables with voltage ≤1000 V and not fitted with connectors, they can be classified under 854449. However, note that optical fibre cables are classified under 9001, not in this chapter. What are the consequences of omitting the "whether fitted with connectors" element during declaration? It may lead to classification errors, thereby affecting tax rates and regulatory conditions. Customs may require supplementary declaration or inspection, and may even impose penalties for inaccurate declaration. What is the main difference between 854449 and 854460? The main difference lies in voltage: 854449 applies to cables with voltage ≤1000 V, and 854460 applies to cables with voltage >1000 V. Accurate rated voltage must be provided during declaration. How does the insulation material of the cable affect classification? The insulation material itself does not determine the 6-digit subheading, but if it is optical fiber, it is classified under 9001. Generally, the insulation material (such as PVC, rubber) does not affect the classification of 854449, but it must be truthfully declared for customs review. Is HS code 854449 applicable when exporting cables to the EU? The first 6 digits of the HS code are internationally universal, and 854449 also applies in the EU. However, the EU may have additional TARIC codes and regulatory requirements, which need to be queried in the EU customs database.
Q: How to query the regulatory conditions and tax rates corresponding to HS code 854449?
A: You can query the regulatory conditions (such as whether CCC certification, export license, etc. are required) and tax rates for this code through the official website of the General Administration of Customs of China or the "Single Window". Tax rates will be adjusted according to policies, and it is recommended to refer to the latest "Import and Export Tariff of the People's Republic of China".
Q: What is the difference in classification between cables fitted with connectors and those not fitted with connectors?
A: Cables fitted with connectors (such as with plugs, connectors) are classified under 854442, and those not fitted with connectors under 854449. During classification, it is necessary to carefully check whether the physical item is fitted with connectors to avoid incorrect declaration.
Q: Under which code should a cable with a voltage of exactly 1000 V be classified?
A: Cables with voltage not exceeding 1000 V (including 1000 V) are classified under 854449 (not fitted with connectors) or 854442 (fitted with connectors). If the voltage exceeds 1000 V, they are classified under 854460.
Q: Are communication cables classified under 854449?
A: If communication cables are coaxial cables, they are classified under 854420; if they are other insulated cables with voltage ≤1000 V and not fitted with connectors, they can be classified under 854449. However, note that optical fibre cables are classified under 9001, not in this chapter.
Q: What are the consequences of omitting the "whether fitted with connectors" element during declaration?
A: It may lead to classification errors, thereby affecting tax rates and regulatory conditions. Customs may require supplementary declaration or inspection, and may even impose penalties for inaccurate declaration.
Q: What is the main difference between 854449 and 854460?
A: The main difference lies in voltage: 854449 applies to cables with voltage ≤1000 V, and 854460 applies to cables with voltage >1000 V. Accurate rated voltage must be provided during declaration.
Q: How does the insulation material of the cable affect classification?
A: The insulation material itself does not determine the 6-digit subheading, but if it is optical fiber, it is classified under 9001. Generally, the insulation material (such as PVC, rubber) does not affect the classification of 854449, but it must be truthfully declared for customs review.
Q: Is HS code 854449 applicable when exporting cables to the EU?
A: The first 6 digits of the HS code are internationally universal, and 854449 also applies in the EU. However, the EU may have additional TARIC codes and regulatory requirements, which need to be queried in the EU customs database.
⚠️ Disclaimer: HS code classification, declaration elements, tariff rates and regulatory conditions on this page are for reference only and do not constitute legal advice on customs classification. Tariff rates and regulations are subject to change; the latest announcements from the General Administration of Customs and on-site determinations shall prevail. Please consult professional customs brokers or customs authorities before import/export.