HS Code: 902214
Vehicle-mounted radiotherapy equipment
Languages: 中文 English Español 日本語 한국어 Tiếng Việt ไทย Русский

📋 Code Structure

Chapter
Chapter 90 covers optical, photographic, cinematographic, measuring, checking, medical or surgical instruments and apparatus, precision instruments and apparatus, etc. Goods under this chapter are characterized by high technology content and high added value. When classifying, focus should be placed on function, use, and technical parameters. Medical equipment is usually classified under headings 9018 to 9022, of which 9022 is specifically for X-ray, alpha ray, beta ray, gamma ray and other radiotherapy equipment.
Heading
Heading 9022 includes medical, surgical, dental or veterinary equipment using X-rays or alpha, beta, gamma or other ionizing radiation, as well as radiotherapy equipment. This heading covers both diagnostic equipment (such as CT scanners and X-ray machines) and therapeutic equipment (such as radiotherapy machines and gamma knives), but must be distinguished from radiation equipment for non-medical uses.
Digit Breakdown
Code 902214 is a 6-digit subheading. The first 2 digits "90" represent Chapter 90 (optical, medical and other precision instruments); digits 3-4 "22" represent heading 9022 (radiotherapy equipment); digits 5-6 "14" represent the subheading, specifically referring to vehicle-mounted radiotherapy equipment. This subheading is a further subdivision under 9022, distinguished from other stationary or mobile radiotherapy equipment.
Classification Basis
This product is vehicle-mounted radiotherapy equipment, which is a type of radiotherapy equipment and has the function of being mounted on a vehicle for mobility. It is classified under 9022 rather than 8705 (special purpose vehicles) or 9018 (medical diagnostic equipment) because its core function is radiotherapy, not transport or diagnosis. At the same time, the vehicle-mounted feature does not affect its classification as medical equipment, so it is ultimately classified under 902214.

📝 Declaration Elements

Product Name
Declare the product name, which should accurately reflect the equipment function, such as "vehicle-mounted radiotherapy equipment" or "mobile radiotherapy system."
⚠️ Misreporting as "medical vehicle" or "X-ray vehicle," leading to incorrect classification.
Use
Describe the medical use of the equipment, such as "for tumor radiotherapy" or "for intraoperative radiotherapy."
⚠️ Filling in "medical use" in general terms without specifying the therapeutic use.
Working Principle
Briefly describe the principle by which the equipment generates radiation, such as "generates X-rays through a linear accelerator" or "uses a cobalt-60 radioactive source."
⚠️ Failing to specify the type of radioactive source, affecting subheading determination.
Brand
Fill in the equipment brand, such as "Varian," "Elekta," etc. If there is no brand, fill in "no brand."
⚠️ Confusing brand with model, or omitting it.
Model
Fill in the specific equipment model, such as "TrueBeam STx."
⚠️ Incomplete or incorrect model entry.
Vehicle-mounted or Not
Clearly state whether the equipment is installed on a vehicle, such as "Yes, installed on a truck chassis."
⚠️ Failing to indicate the vehicle-mounted feature, which may result in incorrect classification under another subheading.
Radiation Source Type
Such as "X-ray," "gamma ray," etc., and it must be consistent with the working principle.
⚠️ Confusing the type of radiation source, such as reporting X-ray as gamma ray.
Power
Fill in the rated power of the equipment, such as "6MV."
⚠️ Incorrect unit or omission.
Example:
Product Name: vehicle-mounted radiotherapy equipment; Use: for tumor radiotherapy; Working Principle: generates X-rays through a linear accelerator; Brand: Varian; Model: TrueBeam STx; Vehicle-mounted or Not: Yes, installed on a truck chassis; Radiation Source Type: X-ray; Power: 6MV.
Common Mistakes:

🎯 Classification Logic

Basis
The core basis for classification is the medical use, radiotherapy function, and vehicle-mounted feature of the equipment. According to the Explanatory Notes to the Import and Export Tariff, 9022 covers radiotherapy equipment, while 902214 specifically refers to vehicle-mounted radiotherapy equipment. The following must all be satisfied: 1) used for radiotherapy; 2) installed on a vehicle; 3) has mobility function. If it is only a transport vehicle, it should be classified under 8705.
Confused Codes:
902219 - Other radiotherapy equipment
902219 refers to other radiotherapy equipment not otherwise specified, including stationary or non-vehicle-mounted mobile equipment. 902214 specifically refers to vehicle-mounted equipment, and the difference between the two lies in whether it is installed on a vehicle.
901819 - Other medical diagnostic equipment
901819 is used for diagnosis, such as X-ray machines and CT scanners, and does not have a therapeutic function. 902214 is used for radiotherapy, and its core function is treatment.
870590 - Other special purpose vehicles
870590 refers to special purpose vehicles, such as medical vehicles and radiation vehicles, but if the vehicle itself only provides transport and carrying functions, the equipment may be classified separately. If the equipment is integrated with the vehicle and its main function is treatment, it is classified under 902214.
902221 - Medical equipment using alpha, beta, gamma rays
902221 covers medical equipment using alpha, beta, and gamma rays, but does not specifically refer to vehicle-mounted equipment. 902214 specifically refers to vehicle-mounted radiotherapy equipment, which usually uses X-rays or a linear accelerator.
Self-Check:

❓ FAQ

Q: What is the difference in classification between vehicle-mounted radiotherapy equipment and ordinary radiotherapy equipment?
A: Ordinary radiotherapy equipment is classified under 902219, while vehicle-mounted radiotherapy equipment is classified under 902214. The difference lies in whether it is installed on a vehicle and has mobility. If the equipment is merely fixed on a vehicle but cannot be moved for treatment, it may still be classified under 902219.
Q: How can it be determined whether vehicle-mounted radiotherapy equipment should be classified under 8705?
A: If the vehicle serves only as a means of transport and the equipment can be removed and used independently, the equipment is classified under 902214 and the vehicle under 8705. If the equipment is integrated with the vehicle and the main function is radiotherapy, the whole is classified under 902214.
Q: Is it necessary to provide vehicle chassis information at the time of declaration?
A: Yes, information such as the vehicle chassis model and brand must be provided to prove the vehicle-mounted feature. At the same time, proof of integration between the equipment and the vehicle must be provided, such as installation drawings or technical specifications.
Q: Does the type of radiation source affect classification?
A: Yes. 902214 usually refers to vehicle-mounted equipment using X-rays or a linear accelerator. If gamma rays are used (such as cobalt-60), it may be classified under 902221. It must be declared accurately according to the type of radiation source.
Q: What regulatory documents are required for the import of vehicle-mounted radiotherapy equipment?
A: Usually a medical device registration certificate, radiation safety license, etc. are required. The specific requirements are subject to the customs and drug regulatory authorities. It is recommended to consult the local customs in advance.
Q: If the equipment is second-hand vehicle-mounted radiotherapy equipment, is the classification the same?
A: The classification remains unchanged, still 902214. However, the import of second-hand equipment may involve additional regulatory conditions, such as pre-shipment inspection and licenses. A description of the equipment condition must be provided.
Q: How can the tax rate for 902214 be checked?
A: It can be checked through the official website of the General Administration of Customs, China International Trade Single Window, or the Import and Export Tariff. Tax rates may be adjusted with policy changes, and the latest version should be used.
Q: What are the common errors at the time of declaration?
A: Common errors include failure to indicate the vehicle-mounted feature, confusion between radiotherapy and diagnostic equipment, incorrect declaration of radiation source type, and omission of brand and model. These errors may lead to classification disputes or customs clearance delays.
⚠️ Disclaimer: HS code classification, declaration elements, tariff rates and regulatory conditions on this page are for reference only and do not constitute legal advice on customs classification. Tariff rates and regulations are subject to change; the latest announcements from the General Administration of Customs and on-site determinations shall prevail. Please consult professional customs brokers or customs authorities before import/export.