HS Code: 854441
Cable with connector (voltage ≤ 80V)
Languages: 中文 English Español 日本語 한국어 Tiếng Việt ไทย Русский

📋 Code Structure

Chapter
Chapter 85 covers electrical machinery and equipment and parts thereof; sound recorders and reproducers, television image and sound recorders and reproducers, and parts and accessories of such articles. This chapter is the most concentrated chapter for electromechanical products in the HS classification, covering a wide range of goods from household appliances to industrial electronic equipment. Within the chapter, headings are divided by function or use, such as electric motors, transformers, batteries, insulated wire and cable, etc. Goods in this chapter generally operate on electrical or electronic principles, but attention must be paid to distinguishing them from mechanical appliances of Chapter 84 and optical instruments of Chapter 90.
Heading
Heading 8544 covers insulated wire, cable and other insulated electric conductors; optical fiber cables. Specifically it covers: insulated winding wire; coaxial cable and other coaxial electric conductors; ignition wiring sets and other wiring sets; other electric conductors, for a voltage not exceeding 80 V or 80 V < voltage ≤ 1000 V; optical fiber cables. However, optical fiber cables must be distinguished from 8544.70. Products under this heading must have an insulating layer and are generally used for transmitting electrical energy or signals.
Digit Breakdown
First 2 digits 85: Chapter 85, indicating electrical machinery and equipment and parts thereof. Digits 3-4: 44: Heading 8544, indicating insulated wire, cable and other insulated electric conductors; optical fiber cables. Digits 5-6: 41: Subheading 854441, indicating other electric conductors, for a voltage not exceeding 80 V, fitted with connectors. Specifically, 8544.4 is other electric conductors for a voltage not exceeding 80 V, further divided into 8544.41 (fitted with connectors) and 8544.49 (other). Therefore 854441 specifically refers to cables with a voltage not exceeding 80 V, fitted with connectors.
Classification Basis
The goods are cables fitted with connectors, voltage ≤ 80 V, meeting the description of 8544.41. The adjacent code 8544.42 is for cables fitted with connectors with 80 V < voltage ≤ 1000 V, a different voltage range; 8544.49 is for cables with voltage ≤ 80 V but not fitted with connectors, lacking connectors; 8544.30 is ignition wiring sets, used for vehicles etc., with a specific use. Therefore, correct classification requires satisfying both the voltage and connector conditions.

📝 Declaration Elements

Product Name
Declare the Chinese and foreign language names of the goods, which should be specific and clear, such as "cable with connectors".
⚠️ Only writing "cable" or "connecting wire", without reflecting connectors and voltage.
Use
Explain the application scenario of the cable, such as for computers, mobile phones, home appliances, etc.
⚠️ Use description is too general, such as "for electronic devices".
Voltage
Specify the rated voltage, which must be ≤ 80 V, such as "24 V".
⚠️ Voltage not indicated or incorrectly declared as 220 V.
Whether Fitted with Connectors
Confirm whether one or both ends of the cable are already fitted with connectors, such as USB, DC plugs, etc.
⚠️ Misreporting bare wire as fitted with connectors.
Connector Type
Describe the specific type of connector, such as USB Type-C, HDMI, DC plug, etc.
⚠️ Only writing "with connectors", without specifying the connector type.
Wire Structure
Explain the conductor material, number of cores, cross-sectional area, etc., such as "copper core, 2 cores, 0.5 mm²".
⚠️ Ignoring wire specifications, leading to classification disputes.
Insulation Material
Describe the insulation layer material, such as PVC, rubber, etc.
⚠️ Not providing insulation material information.
Brand and Model
Declare the brand and model; if there is no brand, indicate "no brand".
⚠️ Brand and model declaration is incomplete or incorrect.
Example:
Product Name: cable with connectors; Use: for mobile phone charging; Voltage: 5 V; Whether Fitted with Connectors: yes; Connector Type: USB Type-C; Wire Structure: copper core, 2 cores, 0.5 mm²; Insulation Material: PVC; Brand: Anker; Model: A1234.
Common Mistakes:

🎯 Classification Logic

Basis
The core basis for classification is: 1. The goods are insulated electric conductors; 2. The rated voltage does not exceed 80 V; 3. They are fitted with connectors. All three conditions are indispensable. At the same time, special-purpose cables such as optical fiber cables (854470) and ignition wiring sets (854430) must be excluded. If the voltage exceeds 80 V, classify under 854442; if not fitted with connectors, classify under 854449.
Confused Codes:
854442 - Cables fitted with connectors (80 V < voltage ≤ 1000 V)
The voltage range is different; 854442 applies to cables fitted with connectors above 80 V up to 1000 V, while 854441 applies only to ≤ 80 V.
854449 - Other electric conductors (voltage ≤ 80 V, not fitted with connectors)
854449 is for cables not fitted with connectors; 854441 must be fitted with connectors.
854430 - Ignition wiring sets
Used for ignition systems of vehicles, aircraft, etc., with a specific use, while 854441 is for general-purpose cables.
854470 - Optical fiber cables
Optical fiber cables are composed of optical fibers and transmit optical signals, while 854441 is metal conductor cable that transmits electrical signals.
Self-Check:

❓ FAQ

Q: How to determine whether the cable voltage is ≤ 80 V?
A: Check the rated voltage on the product specification sheet or label; for example, 5 V, 12 V, 24 V, etc. are all ≤ 80 V. If not marked, confirm with the supplier. Note that the voltage is the rated value, not the peak value.
Q: What is the difference in classification between cables fitted with connectors and cables not fitted with connectors?
A: Cables fitted with connectors are classified under 854441 (≤ 80 V) or 854442 (80 V < voltage ≤ 1000 V); those not fitted with connectors are classified under 854449 (≤ 80 V) or 854460 (80 V < voltage ≤ 1000 V). Connectors are the key distinction.
Q: Under which code should USB data cables be classified?
A: USB data cables usually have a voltage of 5 V and are fitted with connectors, so they should be classified under 854441. However, if they are optical fiber USB cables, they should be classified under 854470.
Q: How to declare cables with multiple connectors?
A: When declaring, all connector types must be listed, such as "one end USB Type-C, the other end USB Type-A". Classification still follows 854441, but the declaration elements must be complete.
Q: Under which code should a cable with a voltage of 80 V be classified?
A: According to the subheading notes, 854441 applies to voltage ≤ 80 V, so 80 V itself should be classified under 854441. If the voltage is 80.1 V, it should be classified under 854442.
Q: Under which code should a cable used for an automobile ignition system be classified?
A: If it is an ignition wiring set, it should be classified under 854430, regardless of whether the voltage is ≤ 80 V. However, ordinary automobile cables fitted with connectors and with voltage ≤ 80 V may still be classified under 854441.
Q: How to check the import tariff rate for 854441?
A: Tariff rates may change. The latest rates can be checked through the General Administration of Customs website, the CCPIT, or professional customs brokers. Usually information such as HS code, country of origin, and trade mode must be provided.
Q: What are common errors in declaration?
A: Common errors include: incorrect voltage declaration, unclear connector description, mistakenly classifying optical fiber cables under this code, and ignoring brand and model. It is recommended to check item by item against the declaration elements.
⚠️ Disclaimer: HS code classification, declaration elements, tariff rates and regulatory conditions on this page are for reference only and do not constitute legal advice on customs classification. Tariff rates and regulations are subject to change; the latest announcements from the General Administration of Customs and on-site determinations shall prevail. Please consult professional customs brokers or customs authorities before import/export.