HS Code: 761410
Aluminum stranded wire and cable, with steel core.
Languages: 中文 English Español 日本語 한국어 Tiếng Việt ไทย Русский

📋 Code Structure

Chapter
Chapter 76 covers aluminum and articles thereof, including unwrought aluminum, aluminum powders, aluminum bars, rods, profiles, aluminum wire, aluminum plates, sheets, strip, foil, aluminum tubes, aluminum structures, aluminum containers, aluminum stranded wire, cables, etc. This chapter does not include aluminum compounds (Chapter 28), aluminum tools (Chapter 82), aluminum machine parts (Chapter 84), or aluminum electrical equipment (Chapter 85). Aluminum materials are widely used in electric power, construction, transportation, and other fields due to their light weight, corrosion resistance, and good conductivity.
Heading
Heading 7614 covers aluminum stranded wire, cables, plaited bands, and the like, but does not include aluminum stranded wire with steel core (this heading explicitly includes aluminum stranded wire with steel core). Specifically includes: aluminum stranded wire, aluminum cables, aluminum plaited bands, aluminum ropes, etc., whether or not cut to length, whether or not fitted with fittings. However, insulated wires and cables should be classified under Chapter 85. Products under this heading are mainly used for power transmission and overhead conductors.
Digit Breakdown
First 2 digits 76: represents Chapter 76, i.e., aluminum and articles thereof. Digits 3-4: 14 represents heading 7614, i.e., aluminum stranded wire, cables, plaited bands, and the like. Digits 5-6: 10 represents subheading 761410, specifically aluminum stranded wire and cables with steel core. This subheading specifically refers to aluminum conductor steel-reinforced (ACSR), i.e., aluminum wire stranded around a steel core, where the steel core provides mechanical strength and the aluminum wire provides conductivity. If without steel core, it is classified under subheading 761490.
Classification Basis
The goods are aluminum stranded wire with steel core, which conforms to the description of heading 7614, and subheading 761410 explicitly states 'with steel core'. If without steel core, it is classified under 761490; if it is insulated cable, it is classified under 8544; if it is aluminum rope but not stranded wire, it may be classified under other subheadings of 7614 or 7326. Therefore, the presence of a steel core is the key distinguishing point.

📝 Declaration Elements

Product Name
The specific name of the declared commodity, such as 'aluminum conductor steel-reinforced' or 'aluminum stranded wire with steel core'.
⚠️ Declaring only 'aluminum stranded wire' without specifying the steel core, leading to classification errors.
Material
Specify the materials of aluminum and steel, such as aluminum being pure aluminum or aluminum alloy, and steel being high-strength steel.
⚠️ Ignoring the steel core material, or misreporting it as another metal core.
Structure
Describe the stranded structure, such as the number of aluminum wire layers, number of steel core wires, stranding direction, etc.
⚠️ Not providing stranding details, only writing 'multi-strand'.
Specifications
Include cross-sectional area, number/diameter of aluminum wires, number/diameter of steel core wires, outer diameter, etc.
⚠️ Incomplete specifications, such as only writing cross-sectional area without the number of wires.
Use
Main use, such as overhead power transmission line, ground wire, etc.
⚠️ Use description is too broad, such as 'for electric power'.
Brand
Manufacturer or brand name; if no brand, fill in 'None'.
⚠️ Confusing brand with manufacturer.
Model
Product model, such as JL/G1A-240/30.
⚠️ Incorrect or missing model.
Surface Treatment
Such as whether galvanized, coated with anti-corrosion layer, etc.
⚠️ Ignoring surface treatment, affecting classification or tariff rate.
Example:
Product Name: Aluminum conductor steel-reinforced; Material: aluminum wire is pure aluminum, steel core is galvanized steel wire; Structure: aluminum wire stranded around steel core, 26 aluminum wires, 7 steel core wires; Specifications: cross-sectional area 240mm²/30mm², outer diameter approximately 20mm; Use: overhead power transmission line; Brand: XX; Model: JL/G1A-240/30; Surface Treatment: steel core galvanized.
Common Mistakes:

🎯 Classification Logic

Basis
Core basis for classification: 1. Whether the commodity is aluminum stranded wire; 2. Whether it has a steel core; 3. Whether it is insulated. If it is aluminum stranded wire with steel core and not insulated, it is classified under 761410. If without steel core, it is classified under 761490. If insulated, it is classified under 8544. In addition, it is necessary to confirm whether it is a stranded structure; single-strand aluminum wire is classified under 7605.
Confused Codes:
761490 - Other aluminum stranded wire, cables
This code covers aluminum stranded wire without steel core, such as all aluminum conductor (AAC) or all aluminum alloy conductor (AAAC). The core difference from 761410 is whether it contains a steel core.
854460 - Other insulated wires, cables
This code covers insulated cables, such as aluminum cables with insulation layers. The aluminum conductor steel-reinforced under 761410 usually has no insulation layer and is used as bare overhead conductors.
7605 - Aluminum wire
7605 is single-strand aluminum wire, not a stranded structure. 761410 is multi-strand stranded and with a steel core.
7312 - Iron or steel stranded wire, cables
7312 is iron or steel stranded wire, such as steel stranded wire. 761410 is aluminum stranded wire with steel core, where the main body is aluminum and the steel core only provides strength.
761699 - Other articles of aluminum
761699 is other articles of aluminum not elsewhere specified; if aluminum stranded wire does not meet the specific subheadings of 7614, it may be classified here. However, 761410 explicitly lists aluminum conductor steel-reinforced.
Self-Check:

❓ FAQ

Q: Which HS code should aluminum conductor steel-reinforced be classified under?
A: Aluminum conductor steel-reinforced should be classified under HS code 761410, i.e., 'Aluminum stranded wire, cables, with steel core'. This code specifically refers to products where aluminum wire is stranded around a steel core, used for overhead power transmission. If without steel core, it is classified under 761490; if with an insulation layer, it is classified under 8544.
Q: How to distinguish between 761410 and 761490?
A: 761410 specifically refers to aluminum stranded wire with steel core, while 761490 covers other aluminum stranded wire (such as all aluminum conductor, all aluminum alloy conductor). The key difference is whether it contains a steel core. When declaring, it is necessary to clearly provide steel core information, such as the number of steel core wires, material, etc.
Q: What elements need attention when declaring aluminum conductor steel-reinforced?
A: When declaring, it is necessary to provide: product name (indicating with steel core), material (materials of aluminum and steel), structure (number/diameter of aluminum wires, number/diameter of steel core wires), specifications (cross-sectional area), use (such as overhead power line), brand, model, surface treatment (such as galvanized). Ensure information is complete and accurate to avoid classification errors.
Q: If aluminum conductor steel-reinforced has an insulation layer, which code should it be classified under?
A: If it has an insulation layer, it does not belong to 761410, because 761410 only covers bare stranded wire. Insulated cables should be classified under Chapter 85, specifically 8544 (insulated wires, cables). However, note that overhead insulated cables may be classified under 8544, while bare conductors are classified under 761410.
Q: How to check the tariff rate for aluminum conductor steel-reinforced?
A: Tariff rates vary depending on country, trade agreements, origin, etc. It is recommended to check the latest tariff rates in China Customs' 'Import and Export Tariff' or through the General Administration of Customs website or single window. Also consider free trade agreement rates, such as ASEAN, RCEP, etc.
Q: What are the main uses of aluminum conductor steel-reinforced?
A: Aluminum conductor steel-reinforced (ACSR) is mainly used for overhead power transmission lines because of its high strength, good conductivity, and low cost. The steel core provides mechanical strength, and the aluminum wire provides conductivity, suitable for long-distance high-voltage transmission. It is also used for ground wires, overhead ground wires, etc.
Q: What are the consequences of mistakenly classifying aluminum conductor steel-reinforced under 761490 during declaration?
A: Misclassification may lead to customs inspection, tax recovery, fines, and even affect corporate credit. Because the regulatory conditions and tariff rates for 761410 and 761490 may differ. It is recommended to declare truthfully, provide accurate information, and apply for pre-classification if necessary.
Q: How to determine whether aluminum stranded wire belongs to a 'stranded' structure?
A: A stranded structure refers to multiple single wires twisted together according to certain rules, such as concentric stranding. A single aluminum wire is not stranded and should be classified under 7605. If multiple aluminum wires are stranded, whether or not with a steel core, it belongs to 7614. It can be determined by observing the cross-section and structure.
⚠️ Disclaimer: HS code classification, declaration elements, tariff rates and regulatory conditions on this page are for reference only and do not constitute legal advice on customs classification. Tariff rates and regulations are subject to change; the latest announcements from the General Administration of Customs and on-site determinations shall prevail. Please consult professional customs brokers or customs authorities before import/export.